Fieldserver Modbus To Bacnet

Fieldserver Modbus To Bacnet Rating: 5,5/10 1365 votes

Modbus RTU to BACnet MS/TP or BACnet/IP QuickServer GatewaysPS-QS-1x10-0757QuickServer, by FieldServer, is a high performance, fully configurable, cost effective Building and Industrial Automation gateway for integrators to easily interface devices to networks in commercial buildings and industrial plants.System integrators world-wide have benefited from the value of the powerful line of interoperability gateways offered by FieldServer. Fs 17 download. Now, QuickServer adds to that value by running the same robust FieldServer protocol conversion software on a highly cost effective platform backed by the experience, engineering expertise and proven technical support that integrators have come to expect from ProSoft Technology.The user can preselect two Building Automation System (BAS) drivers (serial, Ethernet and/or LonWorks) to be loaded on the QuickServer at no extra charge.

  1. Modbus Rtu To Bacnet
  2. Bacnet Modbus Gateway

Additional drivers are available at extra cost. Common combinations of drivers include Modbus RTU, Modbus TCP, BACnet/IP ®, BACnet MS/TP, LonWorks ®, JCI Metasys ® N2 and SNMP.

Modbus Rtu To Bacnet

QuickServer is ready to configure for the specific application. All necessary instructions and software are included with QuickServer. If the user prefers the unit to be pre-configured prior to delivery, FieldServer offers a custom configuration service. HardwareField Connections. Ethernet 10/100 RJ45. Serial RS-485 terminal (up to 115K baud). FTT-10 LonWorks portEnvironment.

Operating temperature: -40°F to 167°F (-40°C to 75°C). Relative humidity: 5% to 90% RH, with no condensationPower Requirements. 9 to 30 Vdc or Vac or 5 Vdc. Current draw 279mA @ 12VdcOther. Configuration/Diagnostic utilities.

  1. The EZ Gateway also carries the BTL Mark, ensuring users that it correctly implements the BACnet features claimed. These approvals and certifications, along with our commitment to Modbus and KNX interoperability, assure our customers that we carry only the highest quality of standards-compliant products.
  2. Introducing our new EZ Gateway Modbus to BACnet: the quick and easy Modbus to BACnet integration solution. As an easy-to-use, high-performance protocol gateway, the EZ Gateway makes configuration.

Modbus TCP/IP to BACnet MS/TP or BACnet/IP QuickServer Gateways PS-QS-1x10-0757. QuickServer, by FieldServer, is a high performance, fully configurable, cost effective Building and Industrial Automation gateway for integrators to easily interface devices to networks in commercial buildings and industrial plants.

Fieldserver Modbus To Bacnet

Capacity: 250 or 500 Points. Table, Wall or DIN rail mountPhysical Dimensions (WxDxH).

Bacnet Modbus Gateway

4.5 x 3.2 x 1.6 in. (11.5 x 8.3 x 4.1 cm). 0.4 lbs (0.2 Kg)Approvals. TUV approved to UL 916 standard. CE Mark.

BTL Mark (PS-QS-1010). RoHS Compliant. FCC Part 15 Compliant.